SUCOFEED – corrugated cables 1 5/8" annular Cable design Inner conductor Dielectric Outer conductor Jacket Order/type no. Dimension Jacket version Ø in mm Ø in mm Ø in mm Ø in mm SUCOFEED_1_5/8_LA 1 5/8" low attenuation standard 17.60 41.00 46.50 50.30 SUCOFEED_1_5/8_LA_FR 1 5/8" low attenuation flame retardant 17.60 41.00 46.50 50.30 Electrical data Typ. operating frequency Impedance Capacitance Relative signal propagation Signal delay Max. operating voltage Typ. attenuation at 1 GHz Typ. attenuation at 2 GHz Typ. attenuation at 2.2 GHz Typ. attenuation at 2.5 GHz Typ. attenuation at 3.0 GHz Max. power at 1 GHz (40 °C) Max. power at 2 GHz (40 °C) Max. power at 2.2 GHz (40 °C) Max. power at 2.5 GHz (40 °C) Max. power at 3.0 GHz (40 °C) GHz Ω pF/m % ns/m kVrms dB/100 m dB/100 m dB/100 m dB/100 m dB/100 m kW kW kW kW kW ≤ 2.75 50 ± 1 72.50 92 3.80 5.50 2.25 3.36 3.56 3.84 4.02 ≤ 4.100 ≤ 2.899 ≤ 2.764 ≤ 2.593 ≤ 2.495 ≤ 2.75 50 ± 1 72.50 92 3.80 5.50 2.25 3.36 3.56 3.84 4.02 ≤ 4.100 ≤ 2.899 ≤ 2.764 ≤ 2.593 ≤ 2.495 General data Temp. range operating Temp. range installation Typ. weight Min. bending radius °C °C kg/100 m mm −55/+85 −25/+60 110.0 300 −40/+85 −25/+60 130.0 300 For detailed data sheets please go to www.hubersuhner.com and then search for type „SUCOFEED“. 174