RADOX® 4 GKW-AX 1800V M FR Conductor Number of conductors Cross section EN 60228, class 5 1 1.5 – 240 mm2 Voltage rating Temperature range single core 1800/3000 V AC 2700/4500 V DC −40 to +120 °C 4 32 1 Composition of cable 1. Conductor 2. Flame barrier 3. Insulation 4. Sheath stranded tin plated copper MICA tape RADOX EI 110, colour: white RADOX EI 109, colour : black Characteristics and specialities • Meets requirement for circuit integrity in case of fire • Resistance to oil, ozone and weathering • Flexible • Easy to strip Application • For applications where circuit integrity is required. • Especially suitable as compact lead wires for systems inside railway rolling stock at fixed or sporadic moving installations. • Recommended for the installation are the standards EN 50355 and EN 50343. Standards Standard DIN 5510-2 EN 50200/EN 50362 EN 45545-2 GOST 31565 UNI CEI 11170-3 Fire protection on railway vehicles hazard level circuit integrity in case of fire For further technical details please refer to our data sheet. 1, 2, 3, 4 30 min. (1030 V AC) 140 HUBER+SUHNER Railway products