Specification CPR main class No. of fibers Cable jacket Ø Single cable Ø Approx. weight On request mm 24/48 72 96 144 288 mm 9.8 10.8 11.9 12.4 16.0 mm 2.0 2.0 2.0 2.0 3.0 numbered kg/km 117 135 144 160 276 Mechanical properties Tensile strength during installation in service Min. bending radius 1) during installation in service Crush resistance Impact resistance short-term long-term Wp = 2.21 J N 9000 N 4 x 100 mm 130 mm 90 N/dm 3000 N/dm 1500 Impacts 50 9000 6 x 100 150 100 3000 1500 50 9000 8 x 100 160 110 3000 1500 50 9000 12 x 100 180 150 3000 1500 50 9000 12 x 100 240 160 3000 1500 50 IEC 60794-1-2 E1 IEC 60794-1-2 E11 IEC 60794-1-2 E3 IEC 60794-1-2 E4 Thermal properties Temperature range during installation °C in service °C in storage °C −10 to +50 −40 to +70 −40 to +70 IEC 60794-1-22 F12 Combustion properties Fire load MJ/m 1.4 1.45 1.6 1.8 3.3 Fire propagation Smoke density on a vertical single cable p p p p p IEC 60332-1-2 p p p p p IEC 61034-2 Halogen acid gas Degree of acidity jacket material jacket material p p p p p IEC 60754-1 p p p p p IEC 60754-2 2011/65/EC (RoHS) compliant (EU) No 305/2011 (CPR) classes on request EN 50575 p = passed 101
Print
Download PDF file
Table of contents
Build your own flipbook