Specification Number of fibers Jacket Ø Tube Ø Approx. weight Mechanical properties Tensile strength during installation in service Min. bend radius during installation in service Crush resistance short-term long-term Impact resistance Wp = 2.21 J Repeated bending r = 30 mm Kink resistance r = 7.5 mm Torsion angle = ± 360° length = 500 mm H+S crush resistance short-term long-term Thermal properties Temperature range during installation in service in storage Combustion properties Fire load Fire propagation on a vertical single cable Smoke density Halogen acid gas jacket material Degree of acidity jacket material 2011/65/EC (RoHS) p = passed 2 mm 4.8 mm 0.9 kg/km 25 N N mm mm N/dm N/dm impacts cycles cycles 500 300 10 10 15 000 1500 100 5000 p 1000 N/5 mm 500 N/5 mm 300 °C −10 to +50 °C −25 to +70 °C −25 to +70 MJ/m 0.6 p p p p compliant 4 4.8 0.9 25 500 300 10 10 10 000 1500 100 5000 p 1000 500 300 0.6 p p p p coloured IEC 60794-1-2 E1 IEC 60794-1-2 E11 IEC 60794-1-2 E3 IEC 60794-1-2 E4 IEC 60794-1-2 E6 IEC 60794-1-2 E10 IEC 60794-1-2 E7 HUBER+SUHNER IEC 60794-1-22 F1 IEC 60332-1-2 IEC 61034-2 IEC 60754-1 IEC 60754-2 85