SC/FC simplex patch cords Technical data Specification Cable diameter (Ø) Design acc. to IEC 61754-4/-13 and TIA 604-3/-4-A Thermal and mechanical tests acc. to IEC 61753-1 Side load acc. to GR-326-CORE Tensile load Operating temperature Durability Material Halogen free Chemical resistance RoHS guidelines 2011/65/EU Value 2.0 mm compliant fulfilled fulfilled 100 N –20 to +70 °C min. 1000 mating cycles flame retardant acc. to UL 94 V–0 yes good compliant Optical values Type SM UPC SM APC MM OM1/OM2/OM3/OM4 Measurement method (IL/RL) IL: IEC 61300-3-4 method B RL: IEC 61300-3-6 IL: IEC 61300-3-34 method C RL: IEC 61300-3-6 IL (dB) ≤ 0.30 ≤ 0.30 ≤ 0.50 * RL (dB) ≥ 50 ≥ 65 ≥ 35 *Measurement of the whole assembly 57