Page 2 of 5 INSTALLATION MANUAL Fiber-to-the-Antenna Box (FTTA) Installation Connection of the MASTERLINE Classic One knock-out hole, Ø 26mm for MASTERLINE Classic 24 fiber Two knock-out holes, Ø 16mm for MASTERLINE Classic 12 fiber 1 Open the cover. Remove nut from MASTERLINE Classic. Feed the breakout cables with the LC duplex connector through the hole Ø 26mm (already open) and nut. 2 Tighten the nut Connect LC duplex connectors 12-10 at the leftt side of the patch plate (once around the patch plate) and at the lowest row 3 Connect LC duplex connectors 9-7 at the next row Connect LC duplex connectors 6-4 at the next row 4 Connect LC duplex connectors 3-1 at the top row Note: Instead of connecting the LC duplex connector 10-12 at the lowest row, of course LC duplex connector 1-3 can be connected at the lowest row. Connection of the fiber optic jumper Two M32 cable glands with pre-splitted 6-fold sealing for 12 fiber optic jumper cable Ø 4.8 - 7.0 mm HUBER+SUHNER disclaims any liability resulting from incorrect installation and use, including any damages resulting from the use of tools and accessories other than the ones recommended herein. Any installation performed by unqualified personnel voids the product warranty provided by HUBER+SUHNER. All due care and attention must be exercised when performing the installation of these products. For advice concerning the general handling of these products please contact HUBER+SUHNER.