Installation Manual Fiber-to-the-Antenna Box (FTTA) FTTA box for up to 18 RRH Installation Connection of the MASTERLINE Classic One knock-out hole, Ø 26mm for MASTERLINE Classic 24 fiber Two knock-out holes, Ø 16mm for MASTERLINE Classic 12 fiber 1 Knock-out hole with Ø 26mm for MASTERLINE Classic 24 fiber and knock-out one hole Ø 16mm for MASTERLINE Classic 12 fiber 2 Open the cover. Remove nut from MASTERLINE Classic. Feed the MASTERLINE Classic (24 fiber) breakouts through the hole and nut. 3 Tighten the nut Connect LC duplex connectors at the right side of the patch plate. Start with number 12 to 10 at the lowest row, followed by 9 to 7, 6 to 4 and 3 to 1. 4 Feed the MASTERLINE Classic (12 fiber) breakouts through the hole and nut. HUBER+SUHNER disclaims any liability resulting from incorrect installation and use, including any damages resulting from the use of tools and accessories other than the ones recommended herein. Any installation performed by unqualified personnel voids the product warranty provided by HUBER+SUHNER. All due care and attention must be exercised when performing the installation of these products. For advice concerning the general handling of these products please contact HUBER+SUHNER. HUBER+SUHNER is certified according to EN(AS) 9100, ISO 9001, ISO 14001, ISO/TS 16949 and IRIS. Waiver: Fact and figures herein are for information only and do not represent any warranty of any kind. Document: DOC-0000684002 / Rev. B / Date of publication: 14.01.2021 / uncontrolled copy www.hubersuhner.com Page 2/4
Download PDF file
Build your own flipbook