Connector reference Connector reference General assembly information Length definition and assembly design The assembly lengths are measured using the connector reference plane of straight plug and jack connectors and the pin centerline of right angle connectors. D-shape flat Assembly length Assembly length Standard assembly length tolerances SUCOFLEX®, Sucotest ≤ 200 mm ± 1.0 mm > 200 mm ± 0.5 % Sucoform ≤ 500 mm ± 3.0 mm ≤ 1000 mm ± 5.0 mm ≤ 2000 mm ± 8.0 mm > 2000 mm ± 0.4 % Minibend ± 7.1 mm Multiflex and S-series ≤ 500 mm ≤ 1000 mm ≤ 2000 mm > 2000 mm ± 5.0 mm ± 7.0 mm ± 12.0 mm ± 0.6 % Semi-rigid, Boa-flex, Ever-flex, Steel-flex, Cobra-flex ≤ 500 mm ≤ 1000 mm ≤ 2000 mm > 2000 mm ± 2.0 mm ± 3.0 mm ± 5.0 mm ± 0.3 % Tighter assembly tolerances are available on special request. Please ask your local HUBER+SUHNER partner. Angular displacement and D-shape flat of connectors With HUBER+SUHNER microwave cable assemblies that have right angle or right angle and bulkhead connec- tors the relative angular displacement must be speci- fied as shown in the following sketches. 270° Reference direction Connector A 0° Displacement angle between connectors 90° 180° 0° D-shape flat Connector A D-shape flat Connector B Connector B 90° 8