Diameter Temperature range Attenuation Attenuation Screening at 1 GHz at 6 GHz effectiveness mm °C dB/m dB/m dB 3.2 −40 to +105 0.89 2.65 > 70 (up to 6 GHz) 5.1 −40 to +105 0.56 -- 5.34 −40 to +105 0.51 1.75 > 40 (up to 2 GHz) > 75 (up to 5 GHz) 5.34 −40 to +105 0.54 1.84 > 70 (up to 6 GHz) 4.95 −40 to +85 0.39 1.00 > 90 (up to 6 GHz) 6.15 −40 to +85 0.26 0.68 > 90 (up to 6 GHz) 5.5 −40 to +105 0.28 0.84 > 80 (up to 2.2 GHz) Bending static mm 5 25 30 30 12 19 25 Bending repeated mm 30 50 50 60 50 63 90 Replacement for RG_316_D RG_58 C/U RG_142 B/U RG_400 B/U Diameter Temperature range Attenuation Attenuation Screening at 1 GHz at 6 GHz effectiveness mm °C dB/m dB/m dB 10.6 −40 to +105 0.26 – > 41 (up to 2 GHz) 11.1 −40 to +105 0.31 1.06 > 81 (up to 6 GHz) 10.25 −40 to +85 0.13 0.35 > 90 (up to 6 GHz) 12.78 −40 to +85 0.10 0.29 > 90 (up to 6 GHz) 12.9 −40 to +85 0.10 0.28 > 90 (up to 7.5 GHz) Bending static mm 50 50 25 31 100 Bending repeated mm 100 110 100 127 200 Replacement for RG_213 /U RG_214 /U Diameter Temperature range Attenuation Attenuation Screening at 1 GHz at 6 GHz effectiveness mm °C dB/m dB/m dB 2.8 −40 to +105 0.90 – > 40 (up to 1 GHz) 6.24 −40 to +105 0.49 – > 40 (up to 1 GHz) 10.25 −40 to +85 0.13 – > 90 (up to 3 GHz) Bending static mm 5 35 25 Bending repeated mm 20 60 100 Replacement for RG_179 B/U RG_59 C/U Diameter Temperature range Attenuation Attenuation Screening at 1 GHz at 6 GHz effectiveness mm °C dB/m dB/m dB 10.7 −40 to +85 – – – Bending static mm 55 Bending repeated mm 110 Replacement for RG_22_B/U HUBER+SUHNER Coaxial cables 55