Temperature range °C −40 to +105 −40 to +105 Attenuation at Attenuation at Attenuation at Screening 1 GHz 3 GHz 6 GHz effectiveness dB/m dB/m dB/m dB 1.63 3.11 – > 40 (up to 3 GHz) 1.63 3.11 – > 40 (up to 3 GHz) −40 to +105 1.63 3.08 4.72 > 60 (up to 6 GHz) −40 to +105 0.97 1.86 – −40 to +105 0.97 1.86 – −65 to +165 0.84 1.56 – −25 to +85 1.13 – – > 38 (up to 1 GHz) > 38 (up to 1 GHz) > 41 (up to 1 GHz) > 40 (up to 1 GHz) −65 to +165 1.01 2.01 3.21 > 80 (up to 6 GHz) −40 to +105 0.89 1.75 2.77 > 80 (up to 6 GHz) −40 to +105 0.89 1.75 2.77 > 80 (up to 6 GHz) −40 to +105 0.37 0.70 – > 85 (up to 2 GHz) −25 to +85 0.50 0.96 1.48 > 75 (up to 6 GHz) −20 to +85 0.69 – – > 35 (up to 1 GHz) −40 to +105 0.57 1.08 1.65 > 70 (up to 6 GHz) −40 to +105 0.57 1.08 1.65 > 70 (up to 6 GHz) −40 to +105 0.54 1.07 1.7 > 75 (up to 5 GHz) −25 to +85 0.48 0.93 1.47 > 85 (up to 6 GHz) −40 to +105 0.29 0.65 1.11 > 78 (up to 3 GHz) −40 to +85 0.13 0.24 0.35 > 90 (up to 6 GHz) −25 to +85 0.25 0.52 0.85 > 71 (up to 1 GHz) Bending static mm 5 5 Bending Cable group repeated mm 20 U1 20 U1 5 20 X1 5 30 U2 5 30 U2 15 26 U2 15 28 U2 18 30 U4 5 30 U4 5 30 U4 20 40 X7 25 48 – 25 50 U7 10 40 U11 10 40 U11 25 50 U9 30 54 U9 30 100 U33 25 100 U30 55 108 U32 Temperature range °C −40 to +105 −40 to +105 Attenuation at Attenuation at Attenuation at Screening 1 GHz 3 GHz 6 GHz effectiveness dB/m dB/m dB/m dB 0.86 1.68 – > 40 (up to 1 GHz) 0.86 1.68 – > 40 (up to 1 GHz) −25 to +85 0.89 – – > 50 (up to 1 GHz) Bending static mm 7 7 Bending Cable group repeated mm 20 U5 20 U5 25 43 X13 HUBER+SUHNER Coaxial cables 53