Series SHV – high voltage connectors Description Content HUBER+SUHNER SHV (Safe High Voltage) connectors provi- Description 351 de more secure handling: centre contacts are well recessed to Interface dimensions in mm/inches 351 prevent shock hazards in unmated condition. When mating a Technical data 352 connector pair the outer conductor contact is made prior to the Cable connectors 353 inner conductor contacts. Receptacles with solder end 355 SHV connectors are suitable for all high voltage applications up to 5 kV DC or 3.5 kV rms. These connectors are typically used in nuclear instruments or test and measurement equipment. Voltages are valid for both, the mated and the unmated condition. Interface dimensions (mm/inches) Plug (male) Jack (female) Plug Jack min. max. min. max. A 4.57/0.180 4.72/0.186 4.83/0.190 4.98/0.196 B 9.78/0.385 9.91/0.390 9.60/0.378 9.70/0.382 C 2.06/0.081 – 2.06/0.081 – D 5.44/0.214 – 5.26/0.207 5.44/0.214 E 1.17/0.046 1.63/0.064 1.55/0.061 1.98/0.078 F 4.42/0.174 – 3.30/0.130 – G 15.90/0.626 16.10/0.634 15.90/0.626 16.00/0.630 H– – 11.59/0.456 12.70/0.500 I– – 1.32/0.052 1.37/0.054 K– – 10.85/0.427 – L– – 1.63/0.064 2.18/0.086 Interface dimensions conformable to the standards: International: USA: IEC 60498, NIM ND-545 MIL-STD-348/314 ANSI N 24.4 SHV HUBER+SUHNER RF connectors – SHV 351