NETWORK Cubes NETWORK CUBE DWDM-MUX-16+UG Unit General Specifications Operating Temperature Storage Temperature Max. optical Power Fiber Type Optical Adapters All ports -5°C to +70°C -40°C to +80°C < 300 mW SMF-28 compatible ∅ 9 / 125 / 250µm to be selected by customer via order code Optical Performance Number of channels Operating channel DWDM Channels Cluster 1 Cluster 2 Upgrade Channel Channel Spacing Insertion Loss DWDM Upgrade Link Loss Isolation 3 DWDM adjacent channels DWDM non-adjacent channels Optical Return Loss Directivity Polarization Dependent Loss 16+1 two clusters out of: C18 - C25 & C27-C34 C45 - C52 & C54 - C61 remaining channels less adjacent channels to the chosen clusters 100 GHz max 1 typical 2 < 4.5 dB 2.7 dB < 1.0 dB 0.9 dB < 6.5 dB 4.2 dB > 25 dB > 40 dB > 45 dB (for the component, also depends on connectors) > 60 dB < 0.3 dB C-2403_Rev.B 1 Max. insertion loss over channel bandwidth, valid over full operating temperature range and all states of polarization including optical connectors. The typical connector loss is 0.4 dB for a pair of connectors 2 Typical insertion loss is defined as typical value over channel bandwidth, full operating temperature range and all states of polarization including optical connectors. Typical values have been derived with statistical methods from actual production data to reflect the majority of cases. 3 For demux only. HUBER+SUHNER is certified according to EN(AS) 9100, ISO 9001, ISO 14001, ISO/TS 16949 and IRIS. Waiver: Facts and figures herein are for information only and do not represent any warranty of any kind. cubeoptics.com Page 2/4