Installation Manual Fiber-to-the-Antenna Box (FTTA) FTTA box for up to 18 RRH 9 Remove seal of the 2nd cable gland and feed LC duplex connectors from fiber optic jumper 1 to 6 through 2nd cable gland. 10 Connect the LC duplex connector 1 to 6 at the correspondent LC adapter. Tighten the cable gland. Close FTTA box cover 12 Close FTTA box with the cover. Note: Do not over tighten the plastic screws, otherwise the screw head could get damaged HUBER+SUHNER disclaims any liability resulting from incorrect installation and use, including any damages resulting from the use of tools and accessories other than the ones recommended herein. Any installation performed by unqualified personnel voids the product warranty provided by HUBER+SUHNER. All due care and attention must be exercised when performing the installation of these products. For advice concerning the general handling of these products please contact HUBER+SUHNER. HUBER+SUHNER is certified according to EN(AS) 9100, ISO 9001, ISO 14001, ISO/TS 16949 and IRIS. Waiver: Fact and figures herein are for information only and do not represent any warranty of any kind. Document: DOC-0000684002 / Rev. B / Date of publication: 14.01.2021 / uncontrolled copy www.hubersuhner.com Page 4/4